Discover the versatility and precision of the TIG 200PAC/DC TIG Welding Machine, powered by advanced MOSFET inverter technology. This multifunctional powerhouse supports both TIG and MMA welding, offering an array of adjustable features like current, gas post time, and a 2T/4T function to accommodate various welding requirements. Tailor your welding approach with adjustable arc striking current, peak current, and base current, ensuring optimal performance for each task.
Technical Specifications
| Feature | Specification |
|---|---|
| Power Voltage | AC 220V ±15% |
| Rated Input Current | TIG - 36.5 A, MMA - 38 A |
| No-Load Voltage | 68 V |
| Output Current | TIG 10–200 A, MMA 10–160 A |
| Rated Output Voltage | TIG 18.4 V, MMA 26.4 V |
| AC Duty Cycle | 20–80% |
| Pulse Duty Cycle | 10–90% |
| Post-Flow Time | 0–10 sec |
| Pulse Frequency | 0.5–5 Hz |
| Basic Value Current | 10–210 A |
| ARC Initiation Current | 10–210 A |
| Attenuation Current | 0–15 s |
Key Features
- Dual-mode: TIG and MMA functionality in one unit
- Pulse TIG welding with adjustable frequency and duty cycle
- High-frequency start ensures clean arc initiation
- Versatile performance on mild steel, stainless steel, and aluminium
- Foot pedal compatible for precision TIG welding control
Recommended Welding Settings
| Material | Mode | Electrode/Filler | Polarity | Amperage Range | Gas Type | Other Settings |
|---|---|---|---|---|---|---|
| Mild Steel | TIG or MMA | ER70S-6 / E6013 | DCEN (-) | 40–120 A (TIG) / 70–130 A (MMA) | Argon | 2s pre-flow, 3s post-flow, 0.5s slope down |
| Stainless Steel | TIG | ER308L | DCEN (-) | 60–120 A | Argon | Pulsed TIG, 2–4s pre/post flow |
| Aluminium | TIG only | ER4043 / ER5356 | AC | 70–130 A | Argon | 30–40% cleaning balance, HF start required |
Frequently Asked Questions
Why is the arc unstable when welding stainless steel?
This could be due to incorrect polarity or poor shielding gas. Use DCEN (-) polarity and set argon flow to 10–12 L/min. A gas lens improves shielding consistency.
Why won’t the arc strike in TIG mode?
Check that HF Start is selected, the foot pedal is disabled if unused, and the tungsten is clean and properly ground. Use 2% thoriated or lanthanated tungsten for best results.
Why isn’t aluminium welding cleanly?
Ensure you are using AC mode with proper cleaning balance. Use a dedicated tungsten for aluminium like pure or zirconiated types.
Why is the machine overheating or cutting out?
This often happens if the duty cycle is exceeded or the vents are blocked. Allow the unit to cool for 10–15 minutes and clean any dust from the vents.
Why is my foot pedal unresponsive?
Check that the pedal is enabled in the settings menu and that the connector isn’t damaged. Always power off before connecting the pedal.