We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies.
MAC AFRIC 12.5 kVA (10 KW) Standby Petrol Generator (380V)
This Three-phase generator is more than enough, it boasts a sturdy movable frame that is fan-cooled and fitted with an electric start. Suitable for small three-phase workshops or small businesses.
Package Length (cm) | 94.50 |
---|---|
Package Width (cm) | 70.50 |
Package Height (cm) | 86.00 |
Package Weight (kg) | 215.000000 |
Generator Type | Open Frame |
Power Output | 10 KW (12.5 KVA) |
Output Voltage | 380 V (Three Phase) @ 50 HZ |
Amperage | 18 A Per Phase |
Decibel Rating | 75 DB(A) |
Fuel Consumption | 4.06 L/PH @ Full Load |
Type | Petrol Powered |
Tank Capacity | 46 L |
Start Type | Electric Start |
Voltage Regulator | Yes (AVR) |
Oil Capacity | 2 L |
Engine Displacement | 678 CC |
Engine Model | JDP1200E |
Total Running Time | 4-6 Hours |
Technical Specifications
Feature | Specification |
---|---|
Generator Type | Open Frame |
Power Output | 10 KW (12.5 KVA) |
Output Voltage | 380 V (Three Phase) @ 50 HZ |
Amperage | 18 A Per Phase |
Decibel Rating | 75 DB(A) |
Fuel Consumption | 4.06 L/PH @ Full Load |
Type | Petrol Powered |
Tank Capacity | 46 L |
Start Type | Electric Start |
Voltage Regulator | Yes (AVR) |
Oil Capacity | 2 L |
Engine Displacement | 678 CC |
Engine Model | JDP1200E |
Total Running Time | 4-6 Hours |
Specifications Notification
Generators are manufactured to run at 80% of its maximum output when at sea-level and in a neutral climate. Factors such as altitude and temperature can affect the efficiency of your engine therefore, creating less power.
Expert Advice
When deciding on generator size, we recommend considering a machine with 20% more delivery than required. This will prevent overloading and prolong the lifetime of the unit.
Specifications Description
An electrician is required to conduct a load-test to ensure you can make an informed purchase decision based on your needed 18 AMPS per phase.
Generators are manufactured to run at 80% of its maximum output when at sea-level and in a neutral climate. Factors such as altitude and temperature can affect the efficiency of your engine therefore, creating less power.
Limitations of Use:
- Do not use more than 50% of your generator’s rated load for your “first step load”.
- Do not use more than 75% of your generator’s rated load for your “Running load”.
These limitations are set to account for any spikes or drops in current that naturally occur in the combustion process of fuel powered generators.