The Fluke 110 is a versatile multimeter designed for electrical measurement and troubleshooting. Trusted by residential and commercial electricians for maintenance tasks, it delivers professional performance with True-RMS accuracy.

 
 

Technical Specifications

General SpecificationsValue
Maximum Voltage (Terminal to Earth Ground)600 V
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2-033, CAT III 600 V
DisplayDigital: 6,000 counts, updates 4/sec
Bar Graph33 segments, updates 32/sec
Battery9V Alkaline, IEC 6LR61
Battery Life400 hours typical (without backlight)
TemperatureValue
Operating-10 °C to +50 °C
Storage-40 °C to +60 °C
MeasurementRangeResolutionAccuracy
DC Millivolts600.0 mV0.1 mV±0.5% + 2
DC Volts6.000 V / 60.00 V / 600.0 V0.001 V – 0.1 V±0.5% + 2
AC Millivolts (True RMS)600.0 mV0.1 mV±1.0% + 3 (45 Hz–500 Hz)
±2.0% + 3 (500 Hz–1 kHz)
AC Volts (True RMS)6.000 V / 60.00 V / 600.0 V0.001 V – 0.1 V±1.0% + 3 (45 Hz–500 Hz)
±2.0% + 3 (500 Hz–1 kHz)
Continuity600 Ω1 ΩBeeper on < 20 Ω, off > 250 Ω
Detects opens/shorts ≥ 500 μs
Resistance600.0 Ω – 6.000 MΩ0.1 Ω – 0.001 MΩ±0.9% + 1 to +2
Resistance40.00 MΩ0.01 MΩ±5% + 2

Key Features

  • True-RMS AC voltage for accurate measurements on non-linear signals
  • Resistance and continuity testing functions
  • Large white LED backlight to work in poorly lit areas
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated
Write Your Own Review
You're reviewing:Fluke 110 True-RMS Digital Multimeter
Your Rating
More Information
Specifications Description
  • True-RMS Accuracy: Ensures accurate measurements on non-linear signals, critical for troubleshooting electrical installations.
  • Bright LED Backlight: Large white LED backlight for clear visibility in poorly lit areas.
  • Versatile Measurement Functions: Measures resistance, continuity, DC/AC voltage, and more.
  • Min/Max/Average Recording: Captures signal fluctuations to provide a comprehensive view of electrical performance.
  • Safety Rated: CAT III 600 V safety rating ensures reliable protection during electrical testing.

General Specifications

  • Maximum Voltage (between any terminal and earth ground): 600 V
  • Safety: IEC 61010-1, Pollution degree 2; IEC 61010-2-033, CAT III 600 V
  • Display: Digital, 6,000 counts, updates 4/sec; Bar graph, 33 segments, updates 32/sec
  • Operating Temperature: -10 °C to + 50 °C
  • Storage Temperature: -40 °C to + 60 °C
  • Battery: 9V Alkaline, IEC 6LR61
  • Battery Life: 400 hours typical, without backlight